I attended
the NERC CIPC meeting in Atlanta this week. There wasn’t a lot of discussion of
the CIP standards, since they are just one of the topics discussed at those
meetings, and we aren’t currently in the throes of any momentous developments
in CIP. But I was struck by one common theme I heard from a couple of the
speakers, and realized that a lesson I thought the NERC community had learned
over the past four or five years still hasn’t been learned.
The lesson
is simple: If there are gaps or inconsistencies in a NERC standard that
can’t be fixed with a straightforward reading of the text, the only permanent remedy is to write a SAR
(Standards Authorization Request) and draft a new or revised standard that
fixes the problem. There is no other remedy allowed by NERC’s Rules of
Procedure.
NERC has run
into this immutable fact several times in the past (at least regarding CIP),
and has spent a lot of time and effort trying to get around it. Does anybody
remember the 2012 CANs (Compliance Application Notices) and CARs (Compliance
Analysis Reports) that were intended to fix inconsistencies in interpretation
of the CIP v3 requirements? They caused a lot of weeping, wailing and gnashing
of teeth in the NERC community, and they were ultimately withdrawn.
Now let’s go
to CIP v5. After FERC approved v5 in late 2013 and entities took a serious look
at the requirements in 2014, they began to realize there were a lot of problems
with the wording – ambiguities, inconsistencies and just plain holes. NERC
acknowledged there were some problems and vowed to address them in time for
entities to be fully compliant by the faraway date of April 1, 2016.
They
promised a large and shifting array of documents to fix the problems. There may
have been others, but I remember NERC pointing at various times to the V5
Implementation Study, the RSAWs,
Section
11 Supporting Documents, the Lessons
Learned and finally the infamous Memoranda
(which created a huge firestorm,
as a result of which all of them were revoked and removed from the NERC web
site).
All of these
documents fell into one of two types: serious attempts to address gaps or
inconsistencies; or “helpful hints” regarding CIP compliance that didn’t
address wording problems. Documents of the first type (for example, the Lesson
Learned on “Programmable Electronic Devices”, which seemed to many of us to be
a sensible way to fix the problem caused by the fact that the word
“Programmable” in the Cyber Asset definition wasn’t itself defined) were
without exception ultimately withdrawn and removed from NERC’s website – when it
became clear they weren’t just providing implementation guidance but actually
going beyond the strict wording. Documents of the second type were left in
place, and remain there to this day (note that I’m not complaining about the
second type of documents. These certainly did fulfill an important need. But
they didn’t clear up gaps or inconsistencies in the wording of the standards, as they were initially
touted as doing).
Late in
2015, NERC seemed to finally acknowledge the hard truth that I’ve already
stated: The only way to change a NERC standard or definition is to go through
the standards drafting process, which of course usually takes years. They bit
the bullet and called for a new CIP drafting team to fix some problems in CIP
v5 (which were identified by the CIP v5 Transition Advisory Group). When FERC approved
CIP v6 in January of this year, they ordered NERC to make three changes:
clarify the LERC definition, develop requirements for Transient Electronic
Devices at Low impact assets, and protect all Control Center-to-Control Center
communications. These items were added to the new SDT’s SAR.
I supported the new SDT, but pointed out
that the really fundamental problems with CIP v5/v6 weren’t even mentioned in
the SAR. In fact, I later published a list
of important problems that aren’t included in the SAR.
To be
honest, at that point (around April of this year) I assumed that it had finally
become apparent to the NERC community, and especially to NERC itself, that
there was no point in talking any more about ingenious “solutions” to CIP
wording problems, that didn’t involve a new SAR[i]. That is
why I was surprised by three statements that were made at this week’s CIPC
meeting:
1) Tobias
Whitney of NERC always leads a discussion of current developments in the CIP
standards at CIPC meetings. He discussed the recent Technical Conference that
included a day of discussion on the problem of how entities can utilize the
cloud while staying compliant with CIP[ii]. He
said NERC was working on this issue and would put out a paper soon. He implied
that this would settle the matter of how the cloud could be utilized in a CIP
environment.
I pointed out in the meeting that this
paper will certainly be valuable, but it isn’t suddenly going to change the
fact that a strict reading of the CIP standards wouldn’t allow an entity to
utilize the cloud. Tobias didn’t seem to disagree with this, but he also didn’t
state its implication: Unless NERC plans to write a SAR for a new CIP version
to incorporate the cloud (and NERC has made no moves to do that), the only way
that a NERC entity can safely utilize the cloud is to reach an accommodation
with their Regional Entity to allow this. I happen to think that most if not
all of the RE’s will be open to entities that want to utilize the cloud (as
they have been to virtualization);
but I’m also sure a lot of entities will hesitate to move in this direction, until
the cloud is officially recognized in the CIP standards. And I won’t even
venture a guess as to how many years from now that will be!
2) The
second statement was made during a discussion of the VOIP
issue. There, it was again implied that a rigorous, thoughtful analysis of
the wording of the requirements and the BES Cyber Asset definition would
resolve the problem. I’ve got news for you, guys: This has been a serious concern
for at least a couple of years, and has been debated endlessly. At least 7 of
the 8 NERC regions have decided they do not consider VOIP systems to be
automatically BES Cyber Assets; and I believe the eighth region now takes this
position as well. But the problem can’t be fixed permanently until the BCA
definition is changed, which – ta da! – requires a SAR (and while the current
CIP SDT is charged with changing the BCA definition to address two other
problems, they are not charged with addressing this one. Moreover, it is highly
unlikely they will decide to add this to their already-overfull agenda).
3) At
one point, Tobias brought up something I’d forgotten about: that somehow a
number of industry organizations, including the trade associations, have become
empowered to write up “guidance” on CIP compliance questions. I had heard this
before, but couldn’t understand what it meant – and I still can’t. Any
organization has always been empowered to write guidance for its members (and
any others who wish to follow it) on how to comply with any standard – whether a
NERC standard or not. But there is no way that this can be considered some sort
of “official” guidance, which NERC will endorse as something the regional
auditors should follow. And if that’s the case, why even imply that allowing
the organizations to issue guidance is in some way a mitigation of the wording
problems with CIP v5/v6? It isn’t.
You may have
noticed one common theme to all three of the points above: In the end, the only
“interpreters” of the CIP standards that matter are the regions. If the
auditors in a region think a requirement should be interpreted in a particular
way, the entities in that region would be well served to make sure they
understand their thinking, since they are likely to be audited based on that. And
guess what? I doubt there’s any NERC entity in the US who won’t assign the
utmost importance to their own region’s interpretation of a CIP requirement.
But there is
a problem with this: Since the Rules of Procedure say nothing about the regions
having any authority to interpret the standards, no region will ever commit an
interpretation to writing, even in an email. I have heard from a lot of
entities that you have to call up an auditor and ask his or her opinion on an
interpretation question. They might not tell you, of course, but if they do
they will only do it on the phone. Of course, this means that if, three years
from now, a different auditor issues a PV because their interpretation was
different from that of the auditor you talked to, you won’t have any
documentation of what the original auditor told you. So this is obviously not
any sort of permanent solution.
The irony of
this is that, after the CAN/CAR debacle with CIP v3, NERC pointed to CIP v5 as the
version that would finally fix the problem of regional variability in
interpretation of requirements. Not only has v5 (and v6) not fixed that problem,
it has made it worse. Because of the much larger number of gaps and
inconsistencies in the wording of the v5/v6 requirements and definitions, the
regions have now become essential to understanding how to comply. I have said
it a number of times – but never in this blog – that the CIP v5/v6 requirements
only “mean” what your region says they mean. Nothing more, nothing less. So
keep your eye on your region.[iii]
Before I let
you go, repeat after me: There is no way a problem with the wording of a NERC
standard can be permanently fixed, other than by writing a SAR and drafting a
new standard. Ignore anyone who tells you something different.
But before
you say, “Well, then we just need to draft a bunch of SARs and get some new
SDTs to work on fixing the wording problems in CIP v5/v6”, I recommend you read
my next post. This will prove (using advanced mathematics) that we have reached
the limit of changes that can be made in the current prescriptive CIP
standards. If we want to incorporate new areas like virtualization and the
cloud, we will have to move to a non-prescriptive, outcomes-based approach. And
that will be the only way to permanently “fix” the problems with the current
wording (most of which problems will become moot in a non-prescriptive format).
This will
require a complete rewrite of CIP, as well as changes in how the standards are
audited and managed. But the alternative is to have what we have now: a set of
standards whose interpretation is ultimately dependent on the auditors. If this
is your idea of how mandatory standards with million-dollar-a-day penalties
should be interpreted, then you should be happy as a clam now. If you aren’t
comfortable with this, then I suggest you start asking what can be done to change
the situation.
The views and opinions expressed here are my own and don’t
necessarily represent the views or opinions of Deloitte Advisory.
[i]
When I say that a SAR is the only way to change a standard, you may be asking
“How about RFIs (Requests for Interpretation)? They are also permitted in the
NERC Rules of Procedure. An Interpretation is voted on by the NERC ballot body
and approved by FERC, just like a new standard is.” But Interpretations aren’t
meant to clarify problems with wording; they are only to explain wording that
is already in place. So they can’t help with the problems I’m talking about.
Those problems can only be addressed by changes in the wording of the standards
or definitions.
[ii]
There are a number of CIP problems that come up with the cloud. One of the most
important has to do with CIP-004 R3 – R5. For example, if a NERC entity puts
data from an ESP in the cloud, it will most likely reside in one or more huge
server rooms, to which hundreds of technicians may have access. Since any one
of those technicians might in theory be able to walk up to a server with that
data and look at it, a strict reading of the standard would require that each
one of them be vetted by the entity for access to their data before being
allowed in that server room, and that the cloud provider notify the entity when
any of those people leaves their employ. No cloud provider in the world will
ever agree to do this. The provider would need to make sure that all servers that
hold the entity’s data be housed in a locked room, with access granted only to
technicians that have been vetted by the entity. This would effectively destroy
any cloud provider’s business model.
[iii]
I just noticed that I had predicted this situation in a post
a month after FERC approved v5 in 2013. In a footnote, I said “I’m guessing
that, if CIP-002-5 isn’t changed, the way this problem will be finally dealt
with (not solved) is through the Regional Entities taking it upon themselves to
develop their own interpretations. These
won’t have any more force than a NERC interpretation, but since the RE’s are
the ones who do the auditing, it is far more likely the registered entities
will follow the lead of their region.” Of course, I was specifically discussing
problems with CIP-002 here, but the same can be said for any of the v5/v6
standards: the Regional Entities are the only real arbiters of interpretation questions.
This situation will remain until the standards are revised or rewritten
entirely (which is my preference, in case you haven’t noticed that yet).